Stainless Steel Standard Range
End Support WBD ss
Application
In combination with a channel, End Support WBD ss is particularly suitable
- for setting up support structures attached to walls, floors and ceilings
- as a base for frame structures
Installation
Normally, two anchors grouped opposite to each other and along the load axis are sufficient. Only in exceptional cases (e.g. high props in frameworks) four anchors are required.
Tightening torque 40 Nm.
Suitable for stainless steel channels with width 41 mm up to height ≤ 62 mm.
Technical Data
Type | Suitable for channel | A [mm] | s [mm] | B [mm] | b [mm] | h [mm] | C [mm] | ø Screw |
---|---|---|---|---|---|---|---|---|
41/41-62 | 41/41 bis 41/62 | 135 | 6 | 100 | 25 | 11 | 125 | M10 |
The permissible maximum vertical load for ceiling mounting structures fixed by way of at least one traversing bolt (class 8.8) amounts to 7.0 kN.
Material: | Stainless steel A4 |
Working load for wall mounting with channel 41/41 and two anchors of the mentioned load class:
Restrictions σperm ≤ 160 N/mm2 fperm ≤ L/100 for L > 300 mm fperm ≤ 3 mm for L = 200 ... 300 mm | Anchor load classes A = 1.5 kN B = 2.5 kN C = 3.5 kN |