Stabil RB-A
Application
For particularly high static requirements in plant construction. Design similar to DIN 3567. The perforations on both sides allow the application of standardised bolts and threaded rods out of the Sikla product range.
If fixed on both sides by threaded rods M12 or M16 or threaded tubes, we recommend the application of the Support Cone SMD 1. In addition to be applied for the design of Fixed Points or Sliding Supports by welding to T-Sections.
Scope of delivery
Two-piece pipe clamp delivered without bolts.
For suitable bolts, please see chapter "Fixings and Fastenings".
Technical Data
Admissible load valid with fixation on both sides
Size range [mm] | max. adm. load (tension) [kN] | Tightening torque [Nm] |
---|---|---|
14 - 49 | 11.0 | 20 |
57 - 89 | 15.5 | 40 |
96 - 163 | 22.0 | 40 |
164 - 273 | 42.0 | 40 |
317 - 610 | 42.0 | 100 |
The max. permissible load capacity of the connected parts (e.g. anchors) shall be considered.
The max. adm. load capacity is determined by the application of statistical methods resulting from the breaking loads, under observance of a max. adm. deformation of 1.5 mm resp. 2% of the max. stretchable pipe dia.
Material: | Steel, surface black |