Guiding Bracket FW F L/Z
Application
Using this Guiding Bracket it's possible to guide Pipe Shoes with different plate thicknesses. The different versions of Type Z are suitable for the respective specified maximum plate thickness (t)and so additionally allow the absorption of lifting forces.
Scope of delivery
Delivery as set comprising 2 Guiding Brackets.
Installation
Installation on top of Beam Section TP F 80 repectively F 100 with 2 Self Forming Screws FLS F per Guiding Bracket, i.e. per set 4 Self Forming Screws have to be used altogether. You can find the Self Forming Screw in the siFramo chapters (section Siconnect).
For Type Z exists a clearance of 3 mm in the vertical z-axis. Please ensure a clearance of 3 mm in the vertical y-axis for all types.
Technical Data
Type | perm. load Fy [kN] | perm. torque via Fy* [kNm] | perm. load Fz [kN] |
---|---|---|---|
FW F 80, all Types Z | 1.9 | 0.4 | 5.0 |
FW F 80, Typ L | 1.9 | - | - |
FW F 100, all Types Z | 1.9 | 0.4 | 6.4 |
FW F 100, Typ L | 1.9 | - | - |
* the torque is calculated by M = Fy x h, whereas the perm. load for Fy may not be exceeded. Dimension h refers from the middle of the pipe to the top of the base plate.
The perm. loads have been determined by load tests following DIN EN 13480-3 annex J.
The used Pipe Shoe has to be verified separately.
Material: | Steel, HCP |
Approvals / Conformity
* suitable for Sikla Pipe Shoes